2 2 0 6 0 2

Maintaining Catalytic Burn-Off

This fireplace uses a catalytic combustor to increase heat transfer to the room and reduce emissions.

The catalytic combustor
takes dirty smoke and turns it
into extra heat and cleaner
emissions.

NOTE: If the combustor is engaged
(bypass closed) when the fireplace
is still cool, it will not work, leading
to dirty smoke, no extra heat, and a
dirtier combustor.

Warning: The bypass control becomes hot during operation - use gloves or a tool to prevent burns.

Follow the directions below to utilize the combustor to its fullest potential.

•

Keep the by-pass open (pulled out) until the fireplace becomes hot (approximately 15 to 30 minutes).

•

Close the by-pass (push in) when the fireplace is hot.

•

Keep the by-pass closed (pushed in) while the fireplace is operating, except when re-loading.

Hint:

The combustor can be viewed through the glass from below. You will notice the
combustor glowing red when the combustor is working effectively.

oke

Sm

With the by-pass closed (pushed in), the

smoke passes through the combustor.

With the by-pass open (pulled out), the smoke passes through

the by-pass and does not go through the combustor.

Smoke

Combustor

By-Pass

Plate

By-Pass Control

Chimney

Smoke

oke

Smoke

Sm

oke

Sm

oke

Sm

Smoke

•

An optional combustor temperature probe is available from your dealer. It allows you to monitor the