P h 07 k 3 s b 1, Unit identification – Friedrich E07K**B User Manual

Page 3

Advertising
background image

2

3

Serial Number L C M P 00000

Production Run Number

Decade Manufactured

L = 0 C = 3 F = 6 J = 9

A = 1 D = 4 G = 7

Product Line

B = 2 E = 5 H = 8

R = RAC

Year Manufactured P = PTAC

A = 1 C = 3 E = 5 G = 7 J = 9 E = EAC

B = 2 D = 4 F = 6 H = 8 K = 0 V = VPAK

H = DSS

Month Manufactured

A = Jan D = Apr G = Jul K = Oct

B = Feb E = May H = Aug L = Nov

C = Mar F = Jun J = Sep M = Dec

PTAC Serial Number Identification Guide

UNIT IDENTIFICATION

Model Number Code

P H 07 K 3 S B 1

Engineering Digit

Design Series

Options

S = Standard
R = Remote Thermostat
C = Seacoast Protection
X = Seacoast / Remote

Nominal Heater Size

(@ 230V or 265V)
0 = No Heater
2 = 2.5KW
3 = 3.4KW
5 = 5.0KW

Voltage

K = 208/230V - 1Ph. - 60Hz.
R = 265V - 1Ph. - 60Hz.

Nominal Cooling Capacity

07 = 7000 BTUh

09 = 9000 BTUh

12 = 12000 BTUh

15 = 15000 BTUh

System

X = Accessory
E = Cooling with or

without electric heat

H = Heat Pump with

Auxiliary Heat

Series

P = P Series