setaltitude(8)

System Administration

143

NAME

setaltitude - set the altitude of the system or whether or not the air filter installed

SYNOPSIS

setaltitude -s

key=value

setaltitude -h

DESCRIPTION

The setaltitude(8) command sets the altitude of the system or whether or not
the air filter installed.

Whether or not the air filter installed can be specified on the M4000/M5000 servers
only.

Privileges

You must have platadm or fieldeng privileges to run this command.

Refer to setprivileges(8) for more information.

OPTIONS

The following options are supported:

EXTENDED

DESCRIPTION

If the altitude of the system is set, any abnormality in the intake air temperature
can be detected quickly. If the altitude of the system is unknown, set a high
value. However, even if no altitude is set for the system, any abnormality in
temperatures such as the CPU temperature can still be detected, so the system
would not be damaged by a fatal error.

-h

Displays usage statement. When used with other options or
operands, an error occurs.

-s

key=value

The item to be set is specified by key. The following value can be
specified:

altitude

Sets the altitude of the system.

filter

Sets whether or not to install the air filter.
You can specify this on the M4000/M5000
servers only.

When you specified altitude as key, specify the altitude of the
system in value in units of meters (m). An integer equal to or
greater than 0 can be specified, and the specified value is
rounded up to the nearest hundred meters. The default value is 0
meters.

When you specified filter as key, either of the following can be
specified for value:

installed

Air filter is installed.

uninstalled

Air filter is not installed.