testsb(8)

System Administration

469

NAME

testsb - perform an initial diagnosis of the specified physical system board (PSB)

SYNOPSIS

testsb

[ [-q] -{y|n}] [-m diag=mode] location

testsb

[ [-q] -{y|n}] [-m diag=mode] -c {all | expansion}

testsb -v

[ -y|-n] [-m diag=mode] location

testsb -v

[-y|-n] [-m diag=mode] -c {all | expansion}

testsb -h

DESCRIPTION

testsb

(8) command performs an initial diagnosis of the specified PSB.

The testsb(8) command is not available on the M3000 server.

The configuration of the PSB and operation of each device mounted on the PSB are
checked. After the diagnostics, the result is displayed. The PSB must not be
configured in the domain, or the domain in which the PSB configured must be
powered off.

The result also can be seen in "Test" and "Fault" displayed by showboards(8)
command.

Privileges

You must have platadm or fieldeng privileges to run this command.

Refer to setprivileges(8) for more information.