background image

Operating Menus

Model 1501 User's Manual


32

To update system:

1. Insert an empty flash disk into the USB port.

2. Create a folder on flash disk called “DVR Upgrade.”

3. Copy the firmware file to DVR Upgrade folder of the flash disk.

4. Click SYSTEM UPDATE on the System Maintenance screen to upgrade

firmware, and display the progress of the system upgrade.

Note: Do not remove USB flash drive while the upgrade process is

taking place.

5. System automatically reboots.

To restore factory settings;

1. Click DEFAULT SETTING on the System Maintenance screen.

2. Click APPLY. Prompt box displays: “Will lose current para, backup factory set

confirm.”

3. Click OK to recover the factory settings.

PTZ

S

ETUP

(

OPTION

)

The PTZ is an optional feature available on some cameras. This feature is not available on
the cameras supplied with the Model 1501 system, but the system software is PTZ-ready.

Click the PTZ icon on the Advanced Setup screen to display the PTZ setup screen. The
parameters for each channel are set separately. Click APPLY to save the new parameters.

CHANNEL

Channel of PTZ connected

PROTOCOL

Select protocol: Pelco-D, Pelco-P (default is Pelco-D)

BAUD RATE

Select baud rate: 1200, 2400, 4800, or 9600

DATA BIT

Select data bit: 5, 6, 7, or 8 (default setting is 8)