3. Push the cable end through the hole on the cylinder manifold far enough

to allow the flexible strand to be bent.

4. Place “S” hook through the hole in the MA lever.
5. Gently pull cable sheath back into manifold, aligning the groove in sheath

with slot in the manifold.

6. Insert the wire retaining clip provided around the groove in the cable

sheath through the slot in the manifold securing the cable.

WARNING:

• With the “S” hook attached to the MA lever, and the wire retaining clip

not properly installed, any pull on the cable exceeding 20lbs may actuate
the fire extinguisher

• Never install, remove or service the cable when the fire extinguisher is

not securely mounted in its brackets

• Always wear eye protection while servicing any component of your

Fireboy fire extinguisher

Operation of Fireboy Fire Extinguisher

Automatic operation of CG2 and MA2 systems
• Actuation of a Fireboy fire extinguisher occurs at 175°F (79°C) and is

entirely dependent on the intensity of the fire

Manual operation of MA2 Systems

1. Do not wait for automatic actuation.
2. Close all hatches leading to the protected compartment.
3. Shutdown all forced ventilation devices, engines, generators and

electrical systems.

4. Remove the safety pin from the “FIRE” T-handle, and pull firmly.

Signs of actuation