Installation instructions, Wire connections – Fisher & Paykel AeroSmart DG62T27C User Manual

Page 29

Advertising
background image

27

Installation instructions

4-wire connections

Use approved 4-wire Power Supply Cord or a 4-wire Cable for Direct Wiring as described
on page 24.

1

Remove the terminal block cover plate.

2

Insert the power supply cable with a UL listed strain relief through the hole provided in the cabinet

near the terminal block. Do not tighten strain relief screw until wiring connections are complete.

Note: a strain relief must be used.

2

strain relief
clamp sections

strain relief
screws

Fig.30 Inserting the power cord

3

Remove center terminal block screw.

4

Remove appliance ground link by removing the ground connector screw (green screw).

3

4

Remove link

Note: If the appliance is moved back to a 3-wire
installation the ground link must be refitted.

Fig.31 Removing screws

5

Connect ground wire (green) of the power supply cord to the ground conductor green screw.

Tighten screw.

6

Connect the neutral wire (white) of the power supply cord to the center terminal screw of the

terminal block. Tighten screw.

7

Connect the red wire and black wire to the upper and lower terminal block screws marked with

the letter L. Tighten screws.

Fig.32 Connecting wiring

7
6

5

7

8

Refit terminal block cover by inserting the two tabs first on the rear panel of the dryer and

secure cover with securing screw.

9

Tighten Strain Relief screws.

8

9

Fig.33 Refitting terminal block and screws

EN

Advertising
This manual is related to the following products: