In the event of a malfunction (burning smell, etc.), immediately stop operation, turn off the electrical
breaker or disconnect the power supply plug, and consult authorized service personnel.
Merely turning off the unit’s power switch will not completely disconnect the unit from the power
source. Always be sure to turn off the electrical breaker or disconnect the power supply plug to en-
sure that power is completely off.

TROUBLESHOOTING

WARNING!

Symptom

Doesn’t operate immedi-
ately:

Noise is heard:

Smells:

Mist or steam are
emitted:

Airfl ow is weak or stops:

Water is produced from the
outdoor unit:

Problem

● If the unit is stopped and then immediately started again, the com-

pressor will not operate for about 3 minutes, in order to prevent fuse
blowouts.

● Whenever the Power Supply Plug is disconnected and then recon-

nected to a power outlet, the protection circuit will operate for about 3
minutes, preventing unit operation during that period.

● During operation and immediately after stopping the unit, the sound

of water fl owing in the air conditioner’s piping may be heard. Also,
noise may be particularly noticeable for about 2 to 3 minutes after
starting operation (sound of coolant fl owing).

● During operation, a slight squeaking sound may be heard. This is

the result of minute expansion and contraction of the front cover due
to temperature changes.

● During Heating operation, a sizzling sound may be heard occasional.

This sound is produced by the Automatic Defrosting operation.

● Some smell may be emitted from the indoor unit. This smell is the

result of room smells (furniture, tobacco, etc.) which have been
taken into the air conditioner.

● During Cooling or Dry operation, a thin mist may be seen emitted

from the indoor unit. This results from the sudden Cooling of room
air by the air emitted from the air conditioner, resulting in condensa-
tion and misting.

● During Heating operation, the outdoor unit’s fan may stop, and

steam may be seen rising from the unit. This is due to Automatic De-
frosting operation.

● When Heating operation is started, fan speed is temporarily very

low, to allow internal parts to warm up.

● During Heating operation, if the room temperature rises above the

thermostat setting, the outdoor unit will stop, and the indoor unit will
operate at very low fan speed. If you wish to warm the room further,
set the thermostat for a higher setting.

● During Heating operation, the unit will temporarily stop operation

(Max. 15 minutes) as the Automatic Defrosting mode operates.
During Automatic Defrosting operation, the OPERATION Indicator
Lamp will fl ash.

● The fan may operate at very low speed during Dry operation or

when the unit is monitoring the room’s temperature.

● During SUPER QUIET operation, the fan will operate at very low

speed.

● In the monitor AUTO operation, the fan will operate at very low

speed.

● During Heating operation, water may be produced from the outdoor

unit due to Automatic Defrosting operation.

See Page

15

15

15

6

6

6

15

NORMAL

FUNCTION

Before requesting service, perform the following checks: