Error contents, Indoor unit, Outdoor unit leds – FUJITSU RY-36UA User Manual

Page 11

Advertising
background image

Indoor EEPROM abnormal
Outdoor EEPROM abnormal
Indoor room temperature sensor
open
Indoor room temperature sensor
short-circuited
Indoor heat exchanger temperature
sensor open
Indoor heat exchanger temperature
sensor short-circuited
Float switch operated
Indoor signal abnormal
Outdoor signal abnormal
Indoor fan abnormal
Outdoor power source connection
abnormal
Outdoor heat exchanger
temperature sensor open
Outdoor heat exchanger
temperature sensor short-circuited
Outdoor temperature sensor open
Outdoor temperature sensor
short-circuited
Outdoor discharge pipe temperature
sensor or compressor temperature
sensor open
Outdoor discharge pipe temperature
sensor or compressor temperature
sensor short-circuited
Outdoor high pressure abnormal

Outdoor discharge pipe temperature
or compressor temperature sensor
abnormal

OPERATION

lamp (RED)

(2 times)

(2 times)

(3 times)

(3 times)

(4 times)
(5 times)
(5 times)
(6 times)

TIMER lamp

(GREEN)

(2 times)

(3 times)

(3 times)

(4 times)

(4 times)

(5 times)

(5 times)

(6 times)

(7 times)

SWING lamp

(ORANGE)

: 0.1s ON/0.1s OFF (flash)

: OFF

: 0.5s ON/0.5s OFF (flash)

Error contents

Operation can be checked by lighting and flashing of the
display section OPERATION, TIMER, and VERTICAL SWING
lamps.
Perform judgment in accordance with the following.

TEST RUNNING

When the air conditioner is run by pressing the remote control
unit test run button, the OPERATION, TIMER, and VERTICAL
SWING lamps flash slowly at the same time.

ERROR

The OPERATION, TIMER, and VERTICAL SWING lamps
operate as follows according to the error contents.

1. INDOOR UNIT

SWING SWING

TIMER

MANUAL

AUTO

OPERATION

VERTICAL SWING lamp (Orange)
TIMER lamp (Green)

OPERATION lamp (Red)

ERROR CONTENTS

flash

1flash

2 flash

3 flash

4 flash

5 flash

6 flash

7 flash

8 flash

9 flash

10 flash

flash

Lighting

Lighting

Lighting

Lighting

Lighting

Lighting

Lighting

Lighting

Lighting

Lighting

Model abnormal or EEPROM abnormal

Power source connection error

Discharge temp. sensor error

Heat exchanger temp. sensor error

Outdoor temp. sensor error

Communication signal error

Indoor unit error

Discharge temp. abnormal

High pressure abnormal

Compressor temp. abnormal

Compressor temp. sensor error

No error. Protect operation

Dislighting

2. OUTDOOR UNIT LEDS

Heat & Cool model (reverse cycle) only

When a malfunction occurs in the out-
door unit, the LEDs on the circuit board
light to indicate the error. Refer to the
following table for the description of
each error according to the LEDs.

LED1

LED2

Error contents

When the fault is cleared, the LED lamp goes off.
However, for discharge pipe temperature abnormal and high pres-
sure abnormal, the LED lamp lights continuously for 24 hours, as
long as the power is not turned off.