Error contents – Friedrich MW18Y3F User Manual

Page 11

Advertising
background image

Self-diagnosis function table (Flashing LED Display)

* Detailed Trouble Display (secondary level) can be indicated by pressing Test Operation button.

ERROR CONTENTS

Error

Operation

Timer

Error

Operation

Timer

Serial signal
error

Normal

1 sec
blinking

Serial reverse signal error
at operation start up

0.1sec
blinking

0.5sec
2 times

When a signal is not read continuously for 10 secs

from power relay ON immediately after operation starts

>>Cooling 0 code transmission, automatic reset

When a signal is not read for 20 secs thereafter

>>Trouble display continues and power relay OFF

>>Permanent stop
When a signal is not read continuously for 10 secs

from power relay ON immediately after operation starts

>>Cooling 0 code transmission, automatic reset

When a signal is not read for 20 secs thereafter

>>Trouble display continues and power relay OFF

>>Permanent stop

Signal reverse signal error
during operation

0.1sec
blinking

0.5sec
2 times

Serial forward signal error
at operation start up

0.1sec
blinking

0.1sec
blinking

0.1sec
blinking

0.1sec
blinking

0.1sec
blinking

0.1sec
blinking

0.1sec
blinking

0.1sec
blinking

0.1sec
blinking

0.1sec
blinking

0.5 sec
4 times

Normal Serial Forward Signal can not be
received more than 10 secs

>>Releases when it becomes normal

Serial forward signal error
during operation

0.5sec
5 times

Normal Serial Forward Signal can not be
received more than 10 secs ( after receiving
effective forward transfer signal)

>>Releases when it becomes normal

Indoor unit
thermistor
error

0.5sec
2 times

0.1sec
blinking

Indoor temperature
thermistor open

0.5sec
2 times

Thermistor detection value is open when
AC plug is inserted

>>Releases when value becomes normal

Pipe thermistor
open or short

0.5sec
3 times

Thermistor detection value is open or short
when AC plug is inserted

>>Releases

when value becomes normal

Outdoor unit
thermistor
error

0.5sec
3 times

0.1sec
blinking

Discharge thermistor
open or short

0.5sec
2 times

Thermistor detection value is open or short

>>Outdoor unit stops

Releases when it becomes normal

Heat exchanger
thermistor open

0.5sec
3 times

Thermistor detection value is open

>>Outdoor unit stops

Releases when it becomes normal

Outdoor temperature
thermistor open or short

0.5sec
4 times

Thermistor detection value is open or short

>>Outdoor unit stops

Releases when it becomes normal

Indoor unit
control error

0.5sec
4 times

0.1sec
blinking

Forced automatic SW
welded

0.5sec
2 times

Forced Auto SW is ON for more than
10 secs continuously

>>Error is indicated while it is ON
Normal Operation other than error indication

Main relay welded

0.5sec
3 times

Serial Reverse Signal is received 1 min.
after Main relay becomes OFF

>>Error is indicated while serial reverse
signal is input on normal operation
Normal operation except error indication

Power interruption error

0.5sec
4 times

50/60Hz is not detected after 4 secs of
power ON.

>>Error is indicated and unit is stopped

Trouble Display (primary)

Detailed Trouble Display (by Test Button)

Detailed Error Item

In

do

or

In

do

or

In

do

or

In

do

or

In

do

or

O

ut

do

or

O

ut

do

or

O

ut

do

or

Model : MW18Y3F / MR18Y3F