6.6 Troubleshooting

The table below provides common symptoms of equipment troubles and the means to rectify
them.

Symptom Check,

Remedy

Cannot turn on the
power.

•

Check cable between transceiver unit and display unit.

•

Check ship’s mains.

•

Have a suitably qualified technician check the fuse in the transceiver unit.

Bottom echo becomes
irregular.

•

Rough seas. Distance to the bottom changes due to rolling and pitching.

•

Long range selected. Transmission period is longer so ship’s pitching and
rolling are apt to affect detection of echo.

Weak echo

•

Output power set to minimum. Set to maximum, on the COM1 menu.

•

Excessive TVG. Readjust TVG on the appropriate menu (HORZ, VERT,
ES). Note that readjustment of TVG is necessary when gain is adjusted.

Somewhat strange
color

•

[BRILL] key setting too low. Increase brightness with [BRILL] key.

Picture contains noise.

•

Equipment not grounded properly. Check equipment ground.

•

Power cable is too close to the signal cable. Relocate power cable or
signal cable.

•

Debris may be on sea surface. Reject unwanted noise with the
interference rejector on the COM

1 menu.

Picture does not
change when tilt angle
is changed. (Bottom is
not displayed in vertical
fan picture when
bottom is flat.)

•

Problem in tilt mechanism or control line. Contact a FURUNO agent or
dealer for advice.