SETTING THE CHARGING VOLTAGE

The charging voltage (DC/DC output voltage) can be set by connecting external voltage setting resistors (R3,
R4) to the -INE3 terminal. Be sure to select a resistor value that allows you to ignore the on resistor (70

, 1mA)

of the internal FET connected to the OUTD terminal (pin 11).

Battery charging voltage:

V

O

V

O

(V)

=

(R3

+

R4)

/

R4

×

4.2 (V)

METHOD OF SETTING THE CHARGING CURRENT

The charge current (output control current) value can be set with the voltage at the +INE1 terminal (pin 9).

If a current exceeding the set value attempts to flow, the charge voltage drops according to the set current value.

Battery charge current setting voltage : +INE1

+INE1 (V) = 25

×

I1 (A)

×

R

S

(

)

METHOD OF SETTING THE SOFT-START TIME

Upon activation, the IC starts charging the capacitor (Cs) connected to the CS terminal (pin 22).

The error amplifier causes soft-start operation to be performed with the output voltage in proportion to the CS
terminal voltage regardless of the load current of the DC/DC converter.

Soft-start time: ts (Time taken for the output voltage to reach 100 %)

ts (s) := 4.2

×

C

S

(

µ

F)

METHOD OF SETTING THE TRIANGULAR WAVE OSCILLATOR FREQUENCY

The trianguar wave oscillator frequency can be set by the timing resistor (R

T

)

connected the RT

terminal (pin 17).

Triangular wave oscillator frequency: f

OSC

f

OSC

(kHz) := 13630 / R

T

(k

)

< Error Amp.3 >

+
+