Step 1: Before filling the steam cleaner,

make sure that the unit is NOT

plugged in.

Step 2: Press locking trigger to ensure

all internal pressure is released.

Step 3: Turn Safety Cap counter

clockwise until removed.

Step 4: Release locking trigger.

Step 5: Add 28 fl. oz (800 cc) of water

using the filling flask provided.

Do not overfill. Replace

Safety Cap by turning

clockwise - press down firmly to

tighten. Heating time is

approximately 6 minutes. Filling

the boiler with hot water will

shorten heat up time.

Step 6: Plug the unit into a standard

120 volt grounded wall

receptacle. The power “On”

light (Red) will light up.

Step 7: Allow approximately 6 minutes

for water vapor to reach its

working temperature and

pressure. When unit is ready

for use the red light will change

to Green.

Step 8: At the start, some water will

come out from the nozzle. This

is normal.

NOTE: Disconnect steam cleaner from

wall outlet before refilling. It is time to refill

your steam cleaner when there is no more

steam coming out of the nozzle. Because

the water tank is pressurized, use caution

when opening to refill. Depress the trigger

button while you unscrew the safety cap

counterclockwise. Always let unit cool for

5 minutes before refilling the unit with

water.

CAUTION: When refilling the

appliance while it is still hot, the

first drops of water might

bubble up.

WARNING: This appliance is

under pressure. After every use,

press trigger button until all

pressure has been released

before removing safety cap.

Allow unit to cool for five (5)

minutes before refilling.

IMPORTANT:

Always insure that the

unit is “UNPLUGGED” from the wall

receptacle prior to initial filling or re-filling

the water tank. Never attempt to fill this

unit under a water tap, always use the

filling flask provided. Failure to follow

these steps will cause the water tank to

overfill and may pose an electrical safety

hazard.

6

Using Accessories
To use the nylon detail brushes, attach the

nylon bristle brush to the end of the angle

concentrator/brush adapter. (See below.)

CAUTION: When cleaning

windows, always avoid any sudden

changes in temperature to prevent

glass breakage or cracks.

Please note that the window squeegee can
only be used with the
hose. To attach the
window squeegee to
the hose, push it in until
the squeegee locking
button clicks in place on
the hose.
Apply steam abundantly,
rub with the soft spongy end, then remove
excess water and dirt with the glass wiping
edge.
This attachment is very useful for cleaning
large windows, plastic material, ceramic,
tiled or marble surfaces.

To attach the angle concentrator/brush

adapter to the hose, hold the hold grip in

one hand and insert the angle

concentrator/brush adapter into the nozzle

end of the hand grip. Make sure that it

locks in place. (See below.)

Step 2: If the floor brush angle adapter

is not attached to the floor

brush, hold the brush with its

bristles up in your left hand.

With the floor brush angle

adapter pointing downward,

insert it into the hole in the back

of the brush, then turn the floor

brush angle adapter 180°.

Step 3: Insert the electrical power cord

into the wall outlet. Heating

time is approximately 6 minutes

with cold water. Filling the

steam generator with hot water

will shorten heat up time.

Step 1: Connect one of the extension

tubes to the hand grip on the

flexible steam hose. To

attach the extension tubes

one onto the other or

onto the hand grip, press the

locking button ensuring that it

fits into the hole. (See

illustrations.) To disconnect,

repeat the operation by

pressing the locking button

and pulling the two sections

apart.

Using the Steam Cleaner with
Floor Brush

Floor Brush

Angle Adapter

NOTE:

Fit floor brush with

the floor brush

angle adapter

on to the

extension tube.

Extension Tubes

OPERATING INSTRUCTIONS

OPERATING INSTRUCTIONS cont.

ATTACHMENTS

How To Assemble & Use

Refilling With Water

Using the Locking Trigger Button
The steam cleaner has a locking trigger

button. The trigger will lock when you

have pushed it in all the way. To unlock

the steam trigger, just press the locking

trigger button in and the steam trigger

will pop up, stopping the flow of steam.

Angle Concentrator/Brush Adapter

Step 1: Disconnect electrical power

cord from wall outlet.

Step 2: Press trigger button until all

pressure has been released.

Step 3: Allow the unit to cool for

approximately 5 minutes

before refilling with water.

Carefully unscrew safety cap.

Step 4: Slowly pour water using the

filling flask into the boiler.DO

NOT Fill Under a faucet, use

the filling flask provided. DO

NOT OVERFILL. Always

leave approximately 2 1/2

inches between the top of

the unit and the water level.

Step 5: Release the locking trigger.

Step 6: Screw safety cap back on the

appliance and plug appliance

back into wall outlet. Steam will

start to be produced as before.