Caution, 3 display unit, 4 grounding the display unit and transceiver unit – Furuno CH-37 User Manual

Page 24: Mounting considerations

Advertising
background image

1-14

1.3

Display Unit

Mounting considerations

Select the mounting location considering the following conditions:

• Select a location where the display unit can easily be operated while observing

the fishing ground or area surrounding the vessel.

• Locate the unit at least 1 meter away from equipment which contains mag-

nets (radar magnetron, loudspeaker).

• A magnetic compass will be affected if placed

too close to the display unit. Observe the fol-
lowing compass safe distances to prevent de-
viation to a magnetic compass: Standard
compass, 2.2 m, Steering compass, 1.6 m.

• Select a location not exposed to direct sun-

light, water splash or hot air.

• Select a location which accommodates the

viewing angle shown at right.

1.4

Grounding the Display Unit and Transceiver Unit

Ground the equipment with a copper strap or ground wire to prevent interfer-
ence.

Remove vinyl sheath; ground
cable by cable clamp.

Earth terminal

Cable clamp

Signal cable
06S4061

Earth terminal

DISPLAY UNIT

TRANSCEIVER UNIT

Ground the equipment to
prevent electrical shock
and mutual interference.

CAUTION

Figure 1-17 Location of earth terminals on display unit and transceiver unit

Within 45

°

Figure 1-16 Display unit

Advertising