Furuno FSV-30S User Manual

Page 58

Advertising
background image

4-2

2. Remove two upset screws, detach the plugs J503, J502, J501, J504, J506 and J507,

and then pull out the power module.

IFE

S

SC

AN

SC

AN

2D

UA

L

DC

ON

Power Module

VH4P

VH5P

Upset screws
M5x25 SUS 2 pcs.

Protection sheet

Power supply
pcb

Spacer

Detach J503, J502,
J501, J504 and
J506.

Detach J507.

Hole

Pin

Processor unit, front view

3. Fix the power supply pcb (supplied) to the power module with spacers (supplied).
4. Connect two VH connectors (provided on the power module) to the power supply pcb.
5. Set the protection sheet (supplied) to the power supply pcb and fasten it with four

screws.

6. Reattach the power module.
7. Connect between the processor unit and CS-120A as follows.

CS-120A

J201

Processor Unit

YEL

BRN

BRN
BRN

POWER FOR CS-120A port

CIF1 or NMEA2/CIF2
port

L

E

PP

1
2
3

NN
MM
JJ
KK
BB
EE
DD
Z

1
2
3
4
10

24V
0V
GND

TD-H
TD-C
RD-H
RD-C
GND
DSR-C
DSR-H
DTR-H

+24V_H
+24V_C
GND

CIF_TXD_H
CIF_TXD_C
CIF_RXD_H
CIF_RXD_C
SHIELD

37-core cable

10S1258

NJC-203-PM

ORG

PPL

Wiring between processor unit and CS-120A

Note: An echosounder should be connected to the processor unit directly.

Advertising