Continued

bracket (see Figure 14). Secure speed
control to bracket with lock nut by pushing
and turning lock nut with pliers clockwise
until it is tight against bracket.

7. Remove knockout plug from louver panel

by pressing top and bottom retaining clips
(see Figure 11, page 13).

8. Place louver panel, louvers pointing up,

back into framed opening. Align control shaft
with rectangular opening by sliding control
bracket along flange (see Figure 14).

9. Fully seat louver panel into frame open-

ing by gently pressing along ends until
all dimpled retainers have snapped in
place.

10. Place control knob, provided, onto control

shaft (see Figure 14).

11. Check to make sure power cord is com-

pletely clear of blower wheel and there are
no foreign objects in blower wheel. Also,
double check all wire leads and make
sure wire routing is not pinched or in a
precarious position. Correct accordingly.

Caution: never touch blow-

er wheel while in operation.

12. Turn on power to duplex outlet if previ-

ously turned off per warning in column 1,
page 14.

13. Plug in blower power cord to duplex outlet

(see Figure 12, page 14).

Figure 14 - Attaching Speed Control to

Firebox with Panel Louvers

Control
Shaft

Control
Knob

Lock Nut

Speed
Control
Bracket

Lower
Louver

Firebox Face

Hearth
Pan
Flange

Screw
Head and
Top Hole
on Bracket

Lower
Flange

Figure 15 - Location of Wiring Diagram

Decal (Model May Vary From Illustration)

Wiring Diagram
Decal 12" in
Front of Blower

Red

Variable

Fan Switch

Fan Switch

(N.O.)

Green

White

On

110/115

V.A.C.

Blower

Motor

Black

Off

1

2

Black

Blue

(BKT Model
Only)

14. Turn blower on and check for operation.

Turn blower off by turning knob fully coun-
terclockwise before continuing.

15. Peel off backing paper and stick supplied

wiring diagram decal on firebox bottom
approximately 12" in from of blower (see
Figure 15).

16. Replace all panels and/or brick bottom

panel if previously removed.

model bk3 Installation
1. Remove knockout plug from louver panel

by pressing top and bottom retaining clips
(see Figure 11, page 13).

2. Place BK3 fan assembly between two leg

stands with fan blades pointing toward
rear of fireplace (see Figure 16).

Figure 16 - Mounting BK3 Blower

Screws

BK3 Blower

Leg
Stands