firebox front and screen become

very hot when running heater.

Keep children and adults away

from hot surface to avoid burns

or clothing ignition. firebox

will remain hot for a time after

shutdown. allow surface to cool

before touching.

Carefully supervise young chil-

dren when they are in the room

with firebox.

You must operate this fireplace

with the provided fireplace

screen, hood if provided, in

place. Make sure these parts

are in place and screens are

closed before running firebox.

the supplied hood may not be

replaced with a hood which may

be provided with a log heater.

Keep the fireplace area clear and

free from combustible materials,

gasoline and other flammable

vapors and liquids.

SAFETy

Continued

1. Do not use this firebox as a wood-burning

fireplace. Use only decorative unvented
room heaters (log sets).

2. Do not add extra logs or ornaments such

as pine cones, vermiculite or rock wool.
Using these added items can cause
sooting.

3. Do not use blower accessory with model

VFB32NC Series. Use only the provided
hood or appropriate hood accessory. See
Accessories on page 18.

4. Vent-free gas log heaters installed in these

fireboxes require fresh air ventilation to
run properly. See Air for Combustion and
Ventilation,
page 7.

5. Do not run firebox

• where flammable liquids or vapors are

used or stored

• under dusty conditions

6. Do not use this firebox to cook food or

burn paper or other objects.

7. Turn firebox off and let cool before servic-

ing. Only a qualified service person should
service and repair firebox.

8. Operating firebox above elevations of

4,500 feet could cause pilot outage.

9. Do not use the firebox if it has been un-

der water due to the shock hazard that
could result with the blower accessary (if
installed) in place.

LOCAL CODES

Install and use heater with care. Follow all
local codes. In the absence of local codes,
use the latest edition of The National Fuel Gas
Code, ANSI Z223.1/NFPA 54*
. Firebox must
be electrically grounded in accordance with
the National Electrical Code, ANSI/NFPA70
(latest edition).
*Available from:

American National Standards Institute, Inc.

1430 Broadway

New York, NY 10018

National Fire Protection Association, Inc.

Batterymarch Park

Quincy, MA 02269

state of massachusetts: The installation
must be made by a licensed plumber or
gas fitter in the Commonwealth of Mas-
sachusetts.
Sellers of unvented propane or natural
gas-fired supplemental room heaters shall
provide to each purchaser a copy of 527
CMR 30 upon sale of the unit.
Vent-free gas products are prohibited for
bedroom and bathroom installation in the
Commonwealth of Massachusetts.