Field Controls TURBINE TB-1 User Manual

Page 2

Advertising
background image

Page 2

Shaded portions indicate dead or turbulent air.

CAUTION: Do not use the TurboMist™ in a down-flow furnace. (The
type where the heated air output is from the bottom of the furnace.)

INSTALLATION

Refer to Figure 1 and Figure 2 for suggested humidifier locations. Do not
install in a turbulent or dead air space. In installations where more than
one humidifier is used do not place them in a position so that one
obstructs the air flow of the other.

WARNING: Locate the A-COIL before cutting into plenum
chamber.

1. Locate the humidifier as close to an existing water pipe as possible.

(DO NOT INSTALL SADDLE VALVE on any water pipe which is
downstream from a water softener.) Insert baffle if air flow is not
directed properly to make turbine and evaporator revolve. See Figure
2

2. Disassemble humidifier: Pull off cover. Remove bagged float valve

assembly. Remove pan by lifting up and out. (See Figures 3 & 4)

Refer to Figure 5:
3. Peel backing from template sheet and apply to duct or plenum.

4. See instructions on installation template. Drill four 3/32" dia. Holes.

Cut opening in duct as indicated.

5. Use four screws furnished to attach humidifier body to duct. Place

level in humidifier body to make sure humidifier is level front to
back. Shim with thin metal washers at the front flange as
necessary.

Figure 1

Figure 2

Figure 3

Figure 4

Figure 5

Advertising