Installation instructions, Checking the gas type gc36 – Fisher & Paykel GC36 User Manual

Page 10

Advertising
background image

10

Installation Instructions

Checking the gas type

GC36

Burners

NG Orifice

(mm)

NG

BTU (MJ/h) @
0.15psi (4”H

2

0)

LP Orifice

(mm)

LP

BTU (MJ/h) @
0.41psi (11”H

2

0)

RH Rear

1.3 mm

8,000 (8.4 MJ/h)

0.8 mm

8,000 (8.4 MJ/h)

LH Rear

1.3 mm

8,000 (8.4 MJ/h)

0.8 mm

8,000 (8.4 MJ/h)

RH Front Simmer

0.85 mm

3,500 (3.47 MJ/h)

0.55 mm

4,000 (4.2 MJ/h)

LH Front Wok

1.75 mm

12,600 (13.3 MJ/h)

1.05 mm

13,000 (13.7 MJ/h)

Centre

1.45 mm

9,500 (10 MJ/h)

0.85 mm

9,500 (10 MJ/h)

GC912/GC912M

Burners

NG Orifice

(mm)

NG

BTU (MJ/h) @
0.15psi (4”H

2

0)

LP Orifice

(mm)

LP

BTU (MJ/h) @
0.41psi (11”H

2

0)

RH Rear

1.3 mm

8,000 (8.4 MJ/h)

0.8 mm

8,200 (8.7 MJ/h)

LH Rear

1.1 mm

5,800 (6.1 MJ/h)

0.7 mm

5,700 (6.0 MJ/h)

RH Front Simmer

0.85 mm

3,000 (3.2 MJ/h)

0.55 mm

3,500 (3.7 MJ/h)

LH Front

1.3 mm

8,000 (8.4 MJ/h)

0.8 mm

8,200 (8.7 MJ/h)

Centre (GC912)

1.75 mm

14,000 (14.8 MJ/h)

1.05 mm

13,000 (13.7 MJ/h)

Centre (GC912M)

2.15 mm

20,000 (21.1 MJ/h)

1.22 mm

19,000 (20 MJ/h)