Service Manual 20

Troubleshooting Guide

Troubleshooting Guide

In general, possible trouble is classified in two kinds.
The one is called Starting Failure which is caused from an electrical defect, and the other is ineffective Air

Conditioning caused by a defect in the refrigeration circuit and improper application.

Unit runs but poor cooling.

Ineffective Cooling

Satisfactory operation
with temperature
difference of inlet & outlet
air; 44~50°F (7~10°C)

Replacement of unit if
the unit is beyond repair.

Check outdoor coil
(heat exchanger) and
fan operation.

Check heat load
increase.

Check cold air
circulation for smooth
flow.

Check gas leakage.

Clean condenser.

Not on separate circuit

Check inside gas
pressure.

Adjust refrigerant
charge.

Malfunction of
compressor.

Replacement of
compressor.

Check clogging in refrigera-
tion circuit.

Repair clogging in
refrigeration circuit.

Dirty indoor coil
(heat exchanger)

Repair gas leak.

Malfunction of fan.

Clogging of air filter.

Obstruction at air outlet.

Remove obstruction.