Installation - recessed, Installation - surface-mount – Foundations 100-SSE User Manual

Page 3

Advertising
background image

2

NOTE: If installing a surface-mount changing station,

see “Installation - Surface-Mount” section.

Recommended Blocking:

Wood double stud blocking is necessary. Contact an architect and

building official to make sure the blocking is adequate and complies

with building codes (Fig. b).

For A. D. A. compliance, top of lower double stud MUST be 27“

(68.5 cm) from the floor.
1. Slide changer into blocking area and mark mounting hole location

on blocking studs.

HINT: This may require 2 additional people to help hold changer

in position while you are marking the locations.

2. Shim changer for a snug fit.
3. Align holes in changer with marked holes and secure using the

appropriate fasteners (Fig. c).
NOTE: It is installers responsibility to provide correct fastereners

for other substrates.

4. Ensure all seven (7) fasteners are tight.

INSTALLATION - RECESSED

Fig. c

Recess

Mounting

Holes

Recess

Mounting

Holes

Recess

Mounting

Holes

63 1/4" (1607 mm)

Rough-in

Double Stud

Double Stud

Do

ub

le

St

ud

D

ou

bl

e

S

tu

d

3 7/8"

(98.4 mm)

1"

(25.4 mm)

21 3/4"

(552 mm)

Rough-in

63 1/4"

(1607 mm)

For A. D. A.

Compliance

27”

(68.5 cm)

TOP

VIEW

FRONT

VIEW

A. F. F

19.4"

(492 mm)

Fig. b

INSTALLATION - SURFACE-MOUNT

Fig. e

Surface-Mount

Holes

Surface-Mount

Holes

Fig. d

A. F. F

14 3/4

(374.7 mm)

48"

(1219 mm)

on center

Top

For A. D. A.

Compliance

48 1/2”

(123 cm)

Recommended Blocking:

If the walls do not have studs on center, then additional blocking is

necessary (Fig. d).

Contact an architect or building contractor to make sure the

blocking is adequate and complies with building codes.

For A. D. A. compliance, measure up 48 1/2” (123 cm) from the

floor and mark the wall. This locates the position for the top left

attachment hole.
NOTE:

- Changer MUST be mounted to studs (Fig. e).

- This unit incorporates a finishing collar that seats behind

the changer’s outside flange. Center the collar as the unit

is being tightened against the wall (Fig. f).

Fig. f

Collar

Unit

Wall

Advertising