Technical specification – Foster FHG 3L User Manual

Page 8

Advertising
background image

7

Cooling Rate

%

rAtE

70

70

70

70

70

70

70

70

70

70

70

70

70

Compressor Difference

2dlF

2

2

2

2

2

2

2

2

2

2

2

2

2

Condenser Overheat Folder

(OH)

Alarm Temperature

ºC

AL

50

50

50

47

47

47

50

50

50

50

47

47

47

Alarm Temperature Delay

min

Alt

2

2

2

2

2

2

2

2

2

2

2

2

2

Shutdown Temperature

ºC

Sd

55

55

55

52

52

52

55

55

55

55

55

55

55

Shutdown Temperature Delay

min

Sdt

0

0

0

0

0

0

0

0

0

0

0

0

0

Net Folder

(nEt)

Device Identification

nlD

0

0

0

0

0

0

0

0

0

0

0

0

0

Thermostat Probe Calibration

CAL1

-*

-*

-*

-*

-*

-*

-*

-*

-*

-*

-*

-*

-*

Return NRC-100 Default settings
NOTE: Not Cabinet Settings

SdFt

-

-

-

-

-

-

-

-

-

-

-

-

-

-

*) Calibration according to factory test run.
**) Gas Defrost = 1
***) Gas defrost = 0
****) Gas defrost = 15

Technical Specification

Model

Compressor cm3

Total Power Input (W)

(Thermal Heat Rejection)

Run Amps

Compressor Run

Watts

Compressor

Start Current

Fuse

kWh/24h

dB (A)

PREM 125

15 + 15

2022

10.8

1360

20A*

13A

43.0

<59

PREM 195

18 + 18

2934

14.8

1800

20A*

16A

63.2

<59

PRO 90

18

1688

8.3

900

20A

13A

35.8

<59

PRO 130

21

2058

9.9

910

20A

13A

43.9

<59

PRO 195

14 + 14

2954

14.8

1360

20A*

16A

63.7

<59

SLIM 70

10

1248

6.4

460

20A

13A

25.5

<56

SLIM 90

14

1468

7.4

680

20A

13A

30.1

<56

SLIM 120

18

1710

8.4

900

20A

13A

35.1

<56

MINI 90

14

1414

7.1

680

20A

13A

29.5

<56

MINI 120

18

1684

8.3

900

20A

13A

35.3

<56


* For cabinets with 2 compressors fitted there is a 20 second delay between compressor starts so the start current of 20A is not exceeded.

The suction pressure as per climate class 3 (see below) is between -8 and -10

ºC approximately 3.5 bar, with a discharge temperature of +40

ºC (clean condenser)

approximately 17.3 bar.
The cases are designed to work in an ambient temperature not exceeding 25 degrees centigrade (C) with a relative humidity not exceeding 60% (RH) Climate Class 3.


The frontal airflow should be < 0,2m/s

Probes
The probes used are PT-1000 with rating at 0º C of 1000 Ohms. There is not a temperature range but the resistance value is approximately 950 Ohms at - 10º C and 1200
at + 50º C.