Troubleshooting guide, Piping system, Room air conitioner – Friedrich CP10F10 User Manual

Page 17: 17 room air conditioner troubleshooting guide

Advertising
background image

17 Room Air Conditioner

Troubleshooting Guide

Troubleshooting Guide

Piping System

Figure 15 is a brief description of the important components and their function in what is called the refrigeration

system. This will help you to understand the refrigeration cycle and the flow of the refrigerant in the cooling cycle.

MOTOR

COMPRESSOR

OIL

(LIQUID REFRIGERANT)

CAPILLARY TUBE

OUTSIDE COOLING

AIR FOR REFRIGERANT

PASS THROUGH

SUCTION LINE

COOL LOW PRESSURE VAPOR

COOLED

AIR

COMPLETE LIQUID

BOIL OFF POINT

LIQUID

PRESSURE

DROP

ROOM AIR HEAT LOAD

VAPOR INLET

HOT

DISCHARGED

AIR

LIQUID OUTLET

HIGH PRESSURE VAPOR
LIQUID REFRIGERANT
LOW PRESSURE VAPOR

ROOM AIR CONITIONER

EVAPORATOR COILS

CONDENSER COILS

CYCLE OF REFRIGERATION

Figure 15

CAPILLARY TUBE

COMPRESSOR

BLOWER

EVAPORATOR COIL

CONDENSER COIL

FAN

MOTOR

Advertising