Manual Sounder
Operation

1. On the normal or dual-frequency display,

press the soft key MODE/FREQ. When the
plotter/sounder display is displayed, press the
soft key SNDR, and then press the soft key
MODE/FREQ.

2. Select MANUAL.

3. Press the soft key RETURN.

Adjusting the gain

Press the soft key GAIN, and then press

or

to set the gain.

Selecting range

Press the soft key RANGE, and then press

or

to select range.

Shifting the basic range

Press the soft key SHIFT, and then press

or

to shift the basic range.

Suppressing Interference

1. Press the [MENU] key, and then press the

soft key SOUNDER SETUP OPTIONS to
open the sounder setup menu.

DGPS 3D

SOUNDER

SETUP

NOISE LIMITER
CLUTTER
WHITE MARKER
HUE
SIGNAL LEVEL
PICTURE ADVANCE

EDIT

HOLD

EDIT

RANGE
SETUP

SYSTEM

SETUP

RETURN

OFF
4
0
1
OFF
1/1

s

2. Press

or

to select NOISE LIMITER.

3. Press the soft key EDIT.

3. Press

or

to select NL1, NL2 or NL3.

4. Press the soft key RETURN.

Suppressing Low Level
Noise

1. Press the [MENU] key, and then press the

soft key SOUNDER SETUP OPTIONS to
show the sounder setup menu.

2. Press

or

to select CLUTTER.

3. Press the soft key EDIT.

4. Press

or

to select clutter rejection level.

5. Press the soft key RETURN.

Selecting Picture Advance
Speed

1. Press the [MENU] key, and then press the

soft key SOUNDER SETUP OPTIONS to
show the sounder setup menu.

2. Press

or

to select PICTURE ADVANCE.

3. Press the soft key EDIT.

4. Press

or

to select speed.

5. Press the soft key RETURN.

Activating Sounder Alarms

1. Press the [ALARM] key, and then press the

soft key NEXT PAGE to show the alarm 2
menu.

DGPS 3D

ALARM2

EDIT

CLEAR
ALARM

ALARM INFORMATION

BOTTOM ALARM
FISH (B/L) ALARM
FISH (NORMAL)
TEMP. ALARM

OFF
OFF
OFF
OFF

NO ALARM

RETURN

s

2. Press

or

to select the alarm among

BOTTOM, FISH (B/L), FISH (NORMAL) and
TEMP. (temperature).

3. Press the soft key EDIT.

4. Press

or

to select on, and then key in

the range to set.

5. Press the soft key ENTER.