FARGO electronic Digital Audio Board 7KDAB User Manual

Page 52

Advertising
background image

7KDAB, Version 2.0, 19-Aug-2007

Vyex LLC, 2003-2007

47

New Commands

{PW} 16

Stop playback of current speech word

Issuing this command will kill a spoken word currently in progress. It’s intent is to provide a means of halting a long
informational message.

{PW} 24 xxxx

Remove Command From Macro


Removes last command from Macro ‘xxxx’.

Reports “OK” if successful, or “? LAST” if there is only one command left in the macro.

To delete the last command in the macro, you need to delete the macro and re-create it.

{PW} 36 T F xxxx

Modify ID Timers

T = ‘1’ for Transmitter 1, or ‘2’ for Transmitter 2

F = function code

0

Terminate ID timer activity. If ID is pending, it is cancelled.

1

Set ID timer to maximum. ID is NOT triggered.

2

Set ID timer to maximum. ID is immediately triggered.

3

Ensure Normal ID cycle. Start’s ID timer if not already running, otherwise this command has no
effect.

4

Ensure Final ID cycle. Start’s ID timer if not already running, and sets the pending ID flag as
though user activity had occurred. If timer was running, this command has no effect.

5

If ID timer is not running, set the ID timer to maximum and execute macro ‘xxxx’

xxxx

= Macro name for function 5

Example use showing a friendly on the hour ID:


{PW} 28 01 8001 99 99 06 59

;enable on the hour ID’s starting at 6:59am

{PW} 28 02 8002 99 99 21 01

;disable on the hour ID’s ending at 9:01pm


{PW} 20 8001 {PW} 28 00 4000 99 99 99 00

;create hourly scheduler setpoint

{PW} 20 8002 {PW} 28 00

;delete hourly scheduler setpoint


{PW} 20 4000 {PW} 36 5 4001

;if ID timer is not running, call macro 4001

;and start the ID timer running


; Macro 4001 speaks “KA9FUR repeater” and if interrupted by user activity will revert to “KA9FUR” in CW

{PW} 20 4001 {PW} 15 9981 9961 000 0260 0001 0335 0149 0540 0401 0421 9902 54 59 0852 67 20 10 09 15 30 27

Advertising