4. VIDEO SOUNDER OPERATION

4-15

4.11 Alarms

The sounder section has five conditions which generate audio and visual alarms: bottom

alarm, fish alarm (bottom lock), fish alarm (normal) and water temperature alarm

(temperature sensor required).

You may set up the sounder alarms on the SOUNDER ALARM menu, which may be

displayed by pressing the ALARM key.

AUDIO ALARM

INTERNAL BUZZ

BOTTOM ALARM

OFF

TEMPERATURE ALARM

OFF

FISH ALARM

OFF

FISH ALARM (B/L)

OFF

ALARM INFOMATION

NO ALARM

SOUNDER
ALARM

EDIT

CLEAR
ALARM

RETURN

Sounder alarm menu

4.11.1 Audio alarm on/off

The audio alarm sounds whenever an alarm setting is violated. You can enable or disable

the audio alarm as follows:

1. Press the ALARM key to show the ALARM menu.

2. Use the Cursor pad

to select ALARM AUDIO.

3. Press the EDIT soft key to show the audio alarm window.

AUDIO ALARM

¡

INT & EXT BUZZ

¤

INTERNAL BUZZ

¡

OFF

Alarm audio window

4. Use the Cursor pad

to select INT & EXT BUZZ (Internal + External alarm), INTERNAL

BUZZ (Internal alarm) or OFF. External buzzer required to select “INT+EXT BUZZ.” OFF

globally turns the audio alarm on or off for all modes, including radar.

5. Press the ENTER soft key.

6. Press the ALARM key to close the menu.