15 measuring bearing – Furuno FR-8111 User Manual

Page 29

Advertising
background image

1 – 13

1.15 Measuring Bearing

Measuring bearing by cursor

Rotate the trackball to set the cursor intersection
on the center of the target. The bearing to the cur-
sor intersection appears at the bottom of the dis-
play.

Measuring bearing by EBL

1) Press the EBL ON key to enable an EBL. Each

pressing of the key enables the No.1 EBL or
No.2 EBL alternately. The active marker’s
readout is circumscribed.

2) Operate the EBL control to bisect the target

with the EBL.

3) Check the EBL readout at the bottom left cor-

ner of the display.

50.0°R
80.0°R

No.1
EBL

No.2
EBL

Target

No.1 EBL bearing
No.2 EBL bearing

EBL

Figure 1-13 How to measure bearing by EBL

Note 1:

You can display EBL bearing relative to

own ship (relative) or with reference to the north
(True). For further details see 1.38 Selecting Unit
of Range Measurement, Bearing Reference. Bear-
ing reference cannot be selected on the N-type
radar; it is fixed to relative bearing in the HU
mode, and true bearing in CU, NU and TM
modes.

Note 2:

Suffix "T" denotes true bearing (for gy-

rocompass input) and suffix "M" denotes mag-
netic bearing (magnetic compass input).

Erasing EBLs

1) If two EBLs are displayed, press the EBL ON

key to circumscribe the VRM readout of the
VRM you want to keep active.

2) Press the EBL OFF key. The EBL readout and

its associated EBL are erased.

Measuring range by VRM

1) Press the VRM ON key to enable a VRM. Each

pressing of the key enables the No.1 VRM or
No.2 VRM alternately. The active marker’s
readout is circumscribed.

5.03nm
12.5nm

No.1 VRM
No.2 VRM

VRM

Figure 1-11 Location of VRM readouts

2) Operate the VRM control to place the outside

edge of the VRM on the inside edge of the
target.

3) Check the VRM readout at the bottom right

corner of the display to find the range to the
target.

No.1 VRM

No.2 VRM

5.0nm
4.0nm

No.1 VRM range
No.2 VRM range

Target

6.0NM
1.0

VRM

Figure 1-12 How to measure range by VRM

Erasing VRMs

1) If two VRMs are displayed, press the VRM

ON key to circumscribe the VRM readout of
the VRM you want to keep active.

2) Press the VRM OFF key. The VRM readout

and its associated VRM are erased.

Note:

You can select unit of range measurement

for the cursor and VRM on the INITIAL menu.
For further details see 1.37 Selecting Unit of
Range Measurement, Bearing Reference. This
function is not available on the N-type radar; unit
of range measurement is fixed for nautical miles.

Advertising