27 electronic plotting (e-plot), Key. 7) press the menu key, Figure 1-23 plotting – Furuno FR-8111 User Manual

Page 36

Advertising
background image

1 – 20

Trail brilliance

Trail brilliance may be adjusted on the BRILL
menu.

1) Press the MENU key.

2) Select the BRILL menu.

3) Press the ENTER/SELECT

key.

4) Select TRAIL and press the ENTER/SELECT

key.

5) Operate the VRM or EBL control to adjust trail

brilliance.

6) Press the ENTER/SELECT

key.

7) Press the MENU key.

1.27 Electronic Plotting (E-plot)

10 operator-selected targets can be plotted elec-
tronically to assess their motion trends. Five past
positions are marked for each plotted target.

A vector appears as you enter a second plot for a
target and is updated each time a new plot is en-
tered for the target. The vector shows the target
motion trend based on its latest two plots.

Alphanumeric readouts for last-plotted or selected
target appear at the bottom of the display.

It should be noted that the vector and alphanu-
meric target data are not updated in real time, but
only when you enter a new plot.

E-plot requires ship's speed input (automatic or
manual) and a compass signal.

When speed is input by a navigator, own ship
moves in accordance with course; not heading.

Plotting a target

Before plotting a target, select PLOT or ALL on
the MARK & DATA DSP menu.

1) Place the cursor on the target you want to plot,

and press the PLOT SYMBOL key.

2) Watching the E-plot timer on the PLOT mode,

wait at least 30 seconds. Place the cursor on
the plot symbol and press the ENTER/SE-
LECT key. The plot symbol of the target
flashes.

3) While the plot symbol of the target is flash-

ing, place the cursor on the target again and
press the PLOT SYMBOL key. The plot sym-
bol shifts to the new target position and the
previous position is marked by a small dot.

NR

IR2

ES1

EAV1

0.080nm
0.220nm

GUARD1
GUARD2

IN

0.25

NM

0.05
ZOOM
SP
HU

A/C
F3
L-ES

345.6°R
23.0°R

+

105.0°R 00.74nm

AUTO

VRM

EBL

SPEED
MANUAL 30.0kt

HDG 123.4°

TTG

12:34

REL VECTOR

12MIN
01:28

TIME

057.1°R
2.7nm
0.4nm

BRG
RNG
CPA

231.0°R
7.5kt
22.2

COURSE
SPEED
TCPA

Vector

Plot
symbol

Past
position
(max. 5)

Plot data (for )

Figure 1-23 Plotting

Note:

If a certain target once plotted is not plot-

ted again within 12 minutes, the plot symbol of
the target flashes. If you want to continue plot-
ting this target, reacquire it within one minute,
otherwise, the target will be regarded as a "lost
target" and its plot symbol and target data will be
erased. The larger the plotting interval, the less
accurate the plotted target data. Plotting of each
target should normally be made every 3 or 6 min-
utes as far as possible.

Advertising