1 – 27

1.37 Selecting Unit of Range
Measurement, Bearing
Reference

You can select the unit of range measurement for
the VRMs and cursor and bearing reference for
the EBLs.

1) Press the MENU key.

2) Select the INITIAL menu.

3) Press the ENTER/SELECT

key.

4) Select appropriate menu and press the ENTER/

SELECT

key.

CRSR BRG (REL, TRUE)
CRSR RNG (nm, km, sm)
VRM1 RNG (nm, km, sm)
VRM2 RNG (nm, km, sm)
EBL1 BRG (REL, TRUE)
EBL2 BRG (REL, TRUE)

5) Select option desired and press the ENTER/

SELECT

key.

6) Press the MENU key.

1.38 Sector Blanking

Administrations may require the radar to stop
transmitting toward the bridge when it is installed
on the foremast. Two blanking areas can be set at
installation. No echoes appear in the blanking
areas.

Area of no transmission
(no echoes appear)

Figure 1-29 Blank areas where

transmission is suspended

1.39 Alarm Output Signal
On/Off

With connection of an external buzzer (option),
aural alarm signal can be output.

1) Select the TIME ALM menu.

2) Select alarm type and press the ENTER/SE-

LECT key.

TIME ALM OUT: Watch alarm signal
GUARD OUT:

Guard alarm signal

ARPA ALM OUT: CPA/TCPA alarm on

ARP-15

PLOT ALM OUT: Alarms on RP-15

3) Select ON or OFF.