Control kits, Thermal safety switch, Model applications – Field Controls Oil Venting Systems User Manual

Page 10: Control kit installation, Model part no. contact material, Switch type application wmo-1

Advertising
background image

11

Control Kits

Model

Applications

CK-61

All oil-fired systems. Has adjustable electronic post purge.

CK-62

All oil-fired systems. Has thermally activated post purge.

CK-63

All oil-fired systems.
(May require optional delay oil valve for simultaneous burner operation.)

D

raft

Pr

ovi

ng

Sw

itch

Se

co

ndar

y

Safe

ty

Sw

itch

The

rmal

Po

st

Pur

ge

Adj

us

tabl

e

El

ect

ro

ni

c

Po

st

Pur

ge

Control Kit Installation:

CK-63 remote mounted. For use with
120 VAC oil-fired systems. Electronic
post purge is included (shown with
cover off). CK kits can be mounted up
to 100 feet from venter.

RJ

R-

6

12

0V

Re

lay

Control Kit*

Control Kits

Control Kits (CK) control the operation of Power
Venters. See the chart below to select the proper
kit for your application.

Model

Part No.

Contact

Material

Load-Rating

(Amps)

Load-Rating

(Volts)

Normally Closed Switch

Switch Type

Application

WMO-1

46086900

Silver

10 Amps

120 AC

200°F

M

SPDT

Manual reset. Designed for use with power
venting and chimney vented systems for
oil-fired applications.

Thermal Safety Switch

Our thermal safety switches efficiently detect flue gas spillage
due to a blocked flue, continuous down drafting or
inadequate draft condition. With the safety switch wired in
series with the burner circuit, the switch will de-energize the
system’s burner or burner control once it senses the spillage
of hot flue gases. It will not allow the burner to restart until
the switch has been manually reset.

* Control Kits are ETL approved accessories when used in conjunction with the SWG and ComboVent Power Venters.

PPC-4 Post Purge

7137FCHVentGuideOil_New:7137FCHVentGuideOil 5/8/08 10:45 AM Page 11

Advertising