3 control unit, Mounting considerations, Mounting procedure – Furuno FAR-2157-D User Manual

Page 18

Advertising
background image

1-10

1.

Desktop mounting: Fasten the fixing plates to the fixing holes with the hex head bolts (sup-

plied).
Flush mounting: Fasten the display unit to the mounting location, and then attach the fixing

plates with four self-tapping screws.

2. Attach the hood to the display unit (the hood is outside of the fixing plates).
3. Fasten the hood to the fixing plates with four screws supplied (M4x10).

1.3 Control Unit

Mounting considerations

The control unit may be mounted on a desktop, with or without the KB fixing metal (supplied) which

mounts the control unit at an angle. When selecting a mounting location, keep in mind the fol-

lowing points:
• Select a location where the control unit can be operated conveniently while observing the dis-

play screen.

• Locate the unit away from heat sources because of heat that can build up inside the cabinet.
• Locate the equipment away from places subject to water splash and rain.
• Determine the mounting location considering the length of the signal cable between the control

unit and the processor unit. (A 10 m signal cable is attached to the control unit.)

• A magnetic compass will be affected if the control unit is placed too close to it. Observe the com-

pass safe distances on page ii to prevent interference to a magnetic compass.

Mounting procedure

Fixing with KB (keyboard) fixing plate

The KB fixing plate sits the control unit at a comfortable angle, like the retractable legs on a PC

keyboard.
1. Fix the KB fixing plate to the bottom of the control unit.
2. Attach cushions (three for RCU-014, two for RCU-015/RCU-016) to the bottom of the control

unit as shown below.

3. Fix the unit to a desired location with self-tapping screws (local supply).

Control unit RCU-014/015/016, side view

Fixing plate

Fixing hole

Hex head bolt

Cushion

KB fixing plate

Advertising