3 monitor unit (for far-2157), 3 monitor unit, Fabricating the power cable dpyc-2.5 – Furuno FAR-2157-D User Manual

Page 32

Advertising
background image

2-8

2.3 Monitor Unit

Two cables are terminated at the monitor unit: the signal cable from the processor unit (5 m or 10
m cable) and the power cable from the ship's mains. The signal cable comes with a connector pre-
attached to it for connection to the monitor unit. Fabricate the power cable as below. Use cable
DPYC-2.5 (Japan Industry Standard) or the equivalent. Be sure to ground the unit, with IV-8sq
wire (local supply). For MU-190, see the applicable Oprator’s Manual.

Note: Pass the AC line through a double-contact breaker (shipyard supply). Further, for vessels
where the power line is grounded, connect one end of the line to the C (common) terminal and the
other end to the H terminal.

Fabricating the power cable DPYC-2.5

1. Remove the armor from the cable by 40 mm.
2. Remove the vinyl sheath by 35 mm.
3. Remove the insulation from the cores by about 10 mm..
4. Peel paint from the armor by 40 mm.
5. Cover the end of the armor with vinyl tape. Fix crimp-on lugs (FV2-4, blue, supplied) to the

cores.

Fabricating power cable DPYC-2.5

Monitor unit MU-201CR, rear view

40 mm: Peel paint.

Taping

(1)

(2)

(4),
(5)

Armor

35 mm

10 mm

(3)

Approx. 40 mm

DPYC-2.5

Vinyl sheath

Crimp-on lug

SECTIONAL VIEW

Conductor
S = 2.5 mm

2

φ = 2.01 mm

Armor

Cable entrance for signal cable

(Connect end which has no EMI core here.)

Cable entrance for power cable