2. CONNECTIONS

22

How to attach the antenna cable connector N-P-8DFB-CF

Attach the coaxial plug (supplied) to the other end of the coaxial cable to connect to the CU as
follows.

Outer Sheath

Armor

Inner Sheath

Shield

Dimensions in millimeters.)

50

30

Cover with heat-shrink tubing and heat.

30

10

Clamp
Nut

Gasket
(reddish
brown)

Clamp

Trim shield here.

Aluminum Foil

Insulator

Trim aluminum
tape foil here.

1

5

Pin

Shell

Clamp Nut

Solder through
the hole.

Remove outer sheath and armor by the
dimensions shown left.
Expose inner sheath and shield by the
dimensions shown left.

Remove insulator and core by 10 mm.

Twist shield end.

Slip on clamp nut, gasket and clamp as shown
left.

Fold back shield over clamp and trim.

Cut aluminum foil at four places, 90 from one
another.

Fold back aluminum tape foil onto shield and trim.

Expose the insulator by 1 mm.

Expose the conductor (core) by 5 mm.

Slip the pin onto the conductor. Solder them
together through the hole on the pin.

Insert the pin into the shell. Screw the clamp
nut into the shell.
(Tighten by turning the clamp nut. Do not
tighten by turning the shell.)