1. HOW TO INSTALL THE UNIT

14

1.4

Incoming Indicator (option)

Select a location for the incoming indicator by following the information shown below.

• Keep the unit away from water splash.
• Keep the unit away from direct sunlight.
• Set the unit away from the exhaust pipes and vents.
• Follow the recommended compass safe distances shown on page i to prevent the interference

to a magnetic compass.

How to install on the bulkhead or bridge panel

1. Remove four screws from the unit to remove the lid.
2. Fix the case with four 4x16 self-tapping screws (supplied).
3. Reattach the lid with four screws.
4. Connect the cable from the CU.
5. Attach the cable fixture (supplied) with two screws.
6. Fasten the cable to the cable fixture with the cable tie (supplied).

How to install by the flush mount

1. Prepare a cutout in the installation location and make four pilot holes. Refer to the outline

drawings.

2. Set the flush mount plate (supplied) to the cutout and fix it with four 4x16 self-tapping screws

(supplied).

3. Remove four screws from the unit to remove the lid.

45 (1.77

")

4-

φ

5 (0.20

")

15

(0.59

")

90±0.5 (3.54

")

120 (4.72

")

60±0.5 (2.36

")

Inmarsat FleetBroadband

VOLUME

INCOMING INDICATOR

ACK

FIXING HOLES

Case

Cable fixture

Cable from the CU

Remove 4 screws
to remove the lid.

Cable tie