Install Wall Register

20. In adjacent room center the register on the duct

end and push into the duct until the frame is
tight to the wall.


NOTE: The clips on the register are designed to

hold it in place.

Adjust Volume of Airflow Between Rooms


NOTE: The plenum is factory set for maximum

discharge of airflow from front of unit. To adjust
the airflow between 2 rooms, adjust the internal
baffle as follows:


21. Remove plenum discharge grille.


22. Remove 2 screws holding baffle. See Fig 11.















23. Position baffle, and secure for desired airflow

setting. See Table 1.


24. Replace plenum discharge grille.

The Installation of the Lateral Duct Accessory Kit is now complete.

Thank you for purchasing this Friedrich accessory.