1 general, 2 keys used for auto plotter, Notice – Furuno FR-7112 User Manual

Page 36

Advertising
background image

6-2

6.1 General

The Auto Plotter ARP-10 is an optional circuit
board which is accommodated in the display
unit of the FR-7062 radar.

The Auto Plotter permits manual or automatic
acquisition and automatic tracking of up to 10
radar targets. An internal microprocessor cal-
culate target data such as speed and course and
displays the results in alphanumeric and by vec-
tors. To ensure the reliability of the displayed
target data, the radar must be properly adjusted
for minimum sea returns and noise.

Principal specifications

Acquisition and tracking

•

Acquisition of up to 10 targets between 0.2
and 16 nm.

•

Automatic tracking of up to 10 acquired tar-
gets between 0.1 and 16 nm.

Vectors

Vector length: 30 s, 1, 3, 6, 15, 30 min.
Orientation: True velocity or relative velocity

Past positions

5 past positions at intervals of 15, 30 s, 1, 2, 3,
6 min.

Alarm

Visual and audible alarms against targets vio-
lating CPA/TCPA limits; visual alarm against
lost targets.

Target discrimination

A target measuring about 800 m or more in the
radial or circumferential direction is regarded
as a landmass and not acquired or tracked. Ech-
oes smaller than about 800 m are regarded as
true targets.

Heading data required for plotting
function.

NOTICE

6.2 Keys Used for Auto Plotter

The Auto plotter utilizes the following touchpad
keys. Given below is a brief description of these
keys.

MENU:

Displays/Erases the main menu.

SELECT/CANCEL:

(Long press) Terminates plotting of the target
selected with the cursor.

(Short press) Displays the data of target selected
with the cursor.

ACQ/ENTER:

Acquires the target selected with the cursor.

ARP-10 MENU operation

The ARP-10 MENU includes the followings:

Display:

Turns on/off the plot symbols, past positions
and target data.

All Cancel:

Cancels the tracking of all targets.

Vector Ref:

Selects relative vector or true vectors.

Vector Length:

Selects vector time.

History:

Selects past position plot interval.

CPA Set:

Selects CPA alarm limit. When a target is pre-
dicted to come within this limit, an aural alarm
sounds and at the same time the corresponding
target symbol changes to a blinking triangle.

Note: If the preset CPA limit is set at OFF, a
target which is on collision course will not pro-
duce an alarm.

TCPA Set:

Selects TCPA alarm limit.

Auto ACQ:

Turns on/off Auto Acquisition Area.

Advertising
This manual is related to the following products: