8 digital interface (iec 61162-1 edition 1 and 2) – Furuno FR-1500 MARK-3 Series User Manual

Page 101

Advertising
background image

-8.1-

8 DIGITAL INTERFACE (IEC 61162-1 Edition 1 and 2)

1 I/O Sentences for Channel 1

Input

BWC, BWR, DBK *, DBS *, DBT, DPT, GDD *, GGA, GLL, GTD *, HDG, HDM *, MDA *, MTW (*),
RMA, RMB, RMC, VBW, VHB, VTG(*), ZDA

(* ) not recommended in IMO type, * R-Type Only

Output

RSD (every 4 s), TLL * (When A/C RAIN control is pressed.) * R-Type Only

2 I/O Sentences of Channel 2

Channels 2 sentences have priority over channel 1 signals.

Input

DBK *, DBS *, DPT, MDA *, MTW, VBW * R-type only

Output

TTM (Interval: 1-7 tgts, 2.5 sec.; 8-15 tgts, 5.0 sec., 16-20 tgts, 10.0 sec.)

3 I/O Sentences of Channel 3

Heading data, I/O sentences of channels 3 have priority over channel 1 signals when both are
input.

Input

HDB *, HDG, HDM, HDT, VHW * R-type only

Output

None

4 Sentence Description

See pages which follow.

5 Priority

Nav data sentences below are read left to right, and in case of timeout the sentence right of last
read sentence is read. In case of multiple high priority sentences the sentences having the highest
priority is read. ** is read regardless of talker. Timeout is 90 seconds unless specified otherwise.

Advertising