Verifying the hardware operation (hard disk drive) – FUJITSU SPARC Enterprise Server M3000 User Manual
Page 79

Chapter 4
FRU Replacement Preparation
4-11
The showhardconf output continued:
For details, see the manual pages of showhardconf.
2. Confirm the state of the status LEDs of the FRU.
For information on the LED status, see
and
.
4.4.3
Verifying the Hardware Operation (Hard disk
drive)
●
Type the probe-scsi-all command to confirm that the new hard disk drive
has been installed.
OPNL Status:Normal; Ver:0101h; Serial:PP082202R8 ;
+ FRU-Part-Number:CA07082-D911 A1 /541-3306-01 ;
PSU#0 Status:Normal; Serial:EA08210127;
+ FRU-Part-Number:CA01022-0720 02B /300-2193-02 ;
+ Power_Status:On;
+ Type:AC;
PSU#1 Status:Normal; Serial:EA08210131;
+ FRU-Part-Number:CA01022-0720 02B /300-2193-02 ;
+ Power_Status:On;
+ Type:AC;
FANBP_B Status:Normal; Ver:0101h; Serial:PP0821031E ;
+ FRU-Part-Number:CA20399-B12X 004AA/541-3304-01 ;
FAN_A#0 Status:Normal;
FAN_A#1 Status:Normal;
XSCF>