9 dummy load – Furuno FS-1503 User Manual

Page 23

Advertising
background image

3-6

3.9 Dummy Load

The dummy load enables testing of the two-tone alarm. Install the board following the figure
below. CHANGE SYSTEM SETTING 9917 to 1.

J

TX
OUT

TX
IN

E

TB2

TB1

TB3

TB4

E

TB3

TB4

J1

J2

ANT

NOTICE

NOTICE

W3 WIRE ASSY.

W5
WIRE ASSY.

W6
WIRE ASSY.

W4 WIRE ASSY.

Separate wire assemblies
W3 and W4 more than
15 mm from each other.

Fasten wire with cable tie.

Gap between inner wall
and wire should be more
than 15 mm.

Do not route
wires within
this area.

Fasten dummy load
assy. to shield case
with four existing
screws (4 pcs.).

W4 should not touch
TB4 or W3.

Separare these wires: Bend crimp-on
lug attached to TB1 upward; bend
crimp-on lug attached to TB3 downward.

DUMMY CONT

BOARD 05P0670

DUMMY

DUMMY LOAD ASSY.

Figure 3-6 COUPLER board, installation of dummy load

Advertising