6. MAINTENANCE & TROUBLESHOOTING

49

3. Unscrew the connector and then connect the test cable as shown below.

BLK WHT (CABLE-)

CASE < A <

CABLE+ < B <

CABLE- < C <

SHIELD

RED

BLACK

BELDEN 8424 or 8404

TEST CABLE

RED BLK (CABLE+)

> 1
> 2

Underwater splice

To Surface
Processor Unit

Pigtail Connections
(see pin description below)

1

2

SOCKET VIEW

Unscrew connector
and then connect
test cable.

How to connect the test cable to the underwater unit

4. Turn on the Surface Processor Unit and monitor.
5. If the vertical scanning and echo sounder images update properly and depth

and temperature readouts show 0 m and ambient temperature respectively,
the underwater unit is functioning normally.

Note:

If echo test is required, immerse the underwater unit in water (fresh or

salt water) and check for echoes.

6. Turn off the Surface Processor Unit and monitor.
7. Disconnect the test cable and then fasten the connector.
8. Spray the connector with silicone spray.
9. Close the cover. Do not overtighten screws; the case will crack if screws are

overtightened.