7. ALARMS

7.1 Overview

There are seven alarm conditions which
generate both aural and visual alarms.

When an alarm setting is violated, the buzzer
sounds and the name of the alarm being
violated appears on the display. The alarm
icon also appears on the Plotter 1, Plotter 2
and Highway displays. This occurs on both
navigators when they are sharing data.

Alarm status is output to external equipment
through the DATA1 port and the DATA4 port
when it outputs data in NMEA format.

234.0

°

BRG

345.0

°

123

12.3

kn

SOG

NM

COG

Arrival Alarm

Speed Alarm

Press CLEAR to silence beep

Press CLEAR

Press CLEAR to close window

Alarm message

Alarm
icon

34

° 23.456´ N 135° 45.678´ E

RNG

D3D 100m

* SAFE

Figure 7-1 Location of alarm

messages and alarm icon

Clearing the aural and visual alarms

Press the CLEAR key. When the navigators
are sharing data, the "reset alarm signal" is
transmitted to the other navigator to clear
aural and visual alarms there.

Disabling an alarm

Select OFF instead of alarm name on the
appropriate menu. This disables the alarm
on both navigators when they are sharing
data.

7.2 Arrival

Alarm,

Anchor

Watch Alarm

Arrival alarm

The arrival alarm informs you that own ship
is approaching a destination waypoint. The
area that defines an arrival zone is that of a
circle which you approach from the outside
of the circle. The alarm will be released if
own ship enters the circle.

Own ship’s
position

Destination

waypoint

: Alarm range

Alarm
setting

Figure 7-2 How the arrival alarm works


1) Press the MENU ESC key.
2) Press 4 to display the ALARM

SETTINGS menu.

Arrival/Anchor ARRV ANCH Off
Alarm Range 0.100NM
XTE On Off
Alarm Range 0.050NM
Ship Speed In Over Off
Speed Rage 000.0 ~ 025.0kn
Next Page

ALARM SETTINGS 1/2

Over

Ship Speed

MENU : Escape

: Select

ENT : Enter

Figure 7-3 ALARM SETTINGS

menu, page 1/2


3) Press to select Arrival/Anchor.
4) Press or to select ARRV.
5) Press to select Alarm Range.
6) Key in alarm range (0.001-9.999 NM).
7) Press the NU/CU ENT key.
8) Press the MENU ESC key.

When own ship nears a waypoint by the
range set here, the buzzer sounds and the
message "Arrival Alarm" appears.