Input sentences, Load requirements as listner, Ap3-1 – Furuno DP-6 User Manual

Page 87: Gll, rma, rmc

Advertising
background image

AP3-1

APPENDIX 3 Digital Interface

(IEC 61162-1 Edition 2)

Input sentences

GLL, RMA, RMC

Schematic diagram

IEC1162 (NMEA)

CHASSIS

1

RD-A

J2

RD-B

2
3
4
5
6
7
8
9

10

1

2
3

05P0653

J9

P609

W9

C1

1000p

R2

470 CR1

U18

1

3

+12V

1SS133

6

4

TLP121-GB

-12V

R1

4.7k

4.7k

R47

Load requirements as listner

Isolation

Optocoupler

Input impedance

470 ohms

Max. Voltage

±

15V

Threshold

4 mA