Mounting, Grounding, Selection of output data format – Furuno INTERFACE UNIT IF-2500 User Manual

Page 5: Cable fabrication

Advertising
background image

2

Mounting

This unit does not have power switch. If you
do not connect the IF-2500 to power
switchboard or circuit breaker, install an
external power switch (local supply), locating
it near the IF-2500.

•

All dimensions in millimeters.

•

For added support, use nuts, bolts and

washers instead of woodscrews.

•

Leave sufficient space at the sides and rear

of the unit for maintenance and servicing.

Grounding

To prevent mutual interface, run a ground
wire between the earth terminal on the unit
and ship’s superstructure.

Selection of output data format

The output data format is selectable by
changing a jumper block; A for IEC61162-1
and B for NMEA. For example, to select
NMEA for J4, change the jumper block from A
to B on JP401 and JP402. Do the same on J5
thru J9.

Factory setting

Output

Jumper

IEC61162-1

(A)

Current

loop

(B)

J4 JP401/JP402

!

J5 JP501/JP502

!

J6 JP601/JP602

!

J7 JP701/JP702

!

J8 JP801/JP802

!

J9 JP901/JP902

!

Cable fabrication

Use the following cables (Japan Industrial
Standard cables) or the equivalents.

Conductor
S = 0.75 mm

φ

= 1.11 mm

2

TTYCS-1 (Twisted pair cable)

Conductor
S = 0.2 mm

φ

= 0.6 mm

2

CO-SPEVV-SB-C 0.2x2P

Armor

Armor

Vinyl sheath

Shield

Shield

Sheath

Sheath

Current loop or IEC 61162-1 signal

Current loop or IEC 61162-1 signal

φ

=

10.1 mm

φ

=

10.5 mm