Accessories, Replacement parts specifications, Technical service – FMI VFP18MV User Manual

Page 22: Service hints

Advertising
background image

22

105071

UNVENTED PROPANE/LP GAS LOG HEATER

FIREPLACE MANUFACTURERS INC.

ACCESSORIES

Purchase these heater accessories from your
local dealer. If they can not supply these
accessories, call Fireplace Manufacturers
Incorporated’s Parts Department at 1-800-
888-2050 for referral information. You can
also write to the address listed on the back
page of this manual.

FIREPLACE HOOD

Black - HDABK (Part # 01244)
Brass - HDABR (Part # 01245)

For all models. Helps deflect heat away
from mantel or wall above fireplace. Fits
openings 28" to 49" wide.

DAMPER CLAMP - 02017

(Not Shown)

For manually-controlled models. Perma-
nently opens chimney flue damper for vented
operation.

LAVA ROCK - GA6060

(Not Shown)

For all models. Order when additional rock
is desired. (3

1

/

2

lb. bag)

Note:

Use only original replacement parts.

This will protect your warranty coverage for
parts replaced under warranty.

PARTS UNDER WARRANTY

Contact authorized dealers of this product.
If they can’t supply original replacement
part(s), call Fireplace Manufacturers
Incorporated’s Technical Service Depart-
ment at 1-888-427-8322.

When calling Fireplace Manufacturers
Incorporated, have ready

• your name

• your address

• model and serial numbers of your heater

• how heater was malfunctioning

• type of gas used (propane/LP or natural

gas)

• purchase date

Usually, we will ask you to return the defec-
tive part to the factory.

PARTS NOT UNDER
WARRANTY

Contact authorized dealers of this product.
If they can’t supply original replacement
part(s), call Fireplace Manufacturers
Incorporated’s Parts Department at 1-800-
888-2050 for referral information.

When calling Fireplace Manufacturers
Incorporated, have ready

• model number of your heater

• the replacement part number

REPLACEMENT
PARTS

SPECIFICATIONS

18" Variable

24" Variable

30" Variable

Manually-

Manually-

Manually-

Controlled

Controlled

Controlled

Btu (Variable)

16,000/26,000

20,000/33,000

21,500/36,000

Type Gas

Propane/LP Only

Propane/LP Only

Propane/LP Only

Ignition

Piezo

Piezo

Piezo

Manifold Pressure

7.9" W.C.

7.9" W.C.

7.9" W.C.

Inlet Gas
Pressure (in. of water)

Maximum

14"

14"

14"

Minimum*

11"

11"

11"

Shipping Weight

26 lbs.

30 lbs.

34 lbs.

* For purpose of input adjustment

TECHNICAL
SERVICE

You may have further questions about in-
stallation, operation, or troubleshooting.

If so, contact Fireplace Manufacturers
Incorporated’s Technical Service Depart-
ment at 1-888-427-8322.

You can also visit DESA International’s
technical service web site at

www.desatech.com.

When Gas Pressure Is Too Low

• pilot will not stay lit

• burners will have delayed ignition

• heater will not produce specified heat

• propane/LP gas supply may be low

When Gas Quality Is Bad

• pilot will not stay lit

• burners will produce flames and soot

• heater will backfire when lit

You may feel your gas pressure is too low or
gas quality is bad. If so, contact your local
propane/LP gas supplier.

SERVICE HINTS

Advertising