How to Install the Unit

1. To prevent vibration and excess noise,

make sure the unit is installed securely

and firmly.

2. If possible Install the unit where the sunlight

does not shine directly on the unit.

3. The outside of the cabinet must extend

outward for at least 12" and there should

be no obstacles, such as a fence or wall,

within 20" from the back of the cabinet, as

it will prevent heat radiation of the

condenser.

Restriction of outside air will greatly reduce

the cooling efficiency of the air conditioner.

CAUTION: DO NOT cover or block any of the side louvers. All side louvers of the cabinet must remain

4. Install the unit with a rear, downward slope, so the back is slightly lower than the front

(about 1/4" bubble on a level). This will force condensation to flow to the outside.

5. Install the unit with the bottom about 30"- 60" above the floor level.

Window Requirements

NOTE: All supporting parts should be secured to sturdy wood, masonry, or metal.

• This unit is designed for installation in standard

double hung windows with actual opening widths

from 22" to 36".

• The top and bottom window sash must open

sufficiently to allow a clear vertical opening of 15"

from the bottom of the upper sash to the window

stool.

HS

IL

G

NE

exposed and unobstructed to the outside of the structure.