8 operating instructions (cont.) 7 8 9 – Frymaster Cooking Computer KFC-1 SMS User Manual

Page 14

Advertising
background image

1-13

1.8 Operating Instructions (cont.)

7

8

9

Computer displays DONE and an
alarm sounds. Cook cycle is
complete.

Pressing the flashing
product number will
stop the alarm and return
the fryer to selected
standby cycle mode
(COOL, SET--TEMP,
FILTER).

Computer displays COOL
indicating oil/shortening has
cooled to a standby temperature
of 250 °F (121 °C).

Pressing EXIT/COOL
FILTER button will exit
COOL standby mode
and return fryer to a
previous setpoint
temperature.

Computer displays FILTER indicating that a pre-selected
number of cook cycles has been reached and the
oil/shortening needs filtering. If FILTER displays during
a busy time of day, a cook cycle can be initiated.
Computer does not lock out.

If filtering is chosen, open drain valve. The computer
will lock out after drain valve is open for 4 seconds.

Computer display alternates between DRAIN and OPEN, indicating that drain valve is open,
and the computer is locked out.

After drain valve is open for 30 seconds, Computer display alternates between DRAIN,
OPEN and FILL, indicating that the filtering process can be initiated.