Pre-planning your ductwork ductless installations, Ducted, Ducted ductless – Faber AXIA ISOLA 630000815 User Manual

Page 2

Advertising
background image

upper

chimney

cover

ductless

lower

chimney

cover

canopy

cabinet base

x = distance from hood to cooktop

(varies depending on installation)

min - 24”, suggested max - 30”

also consult cooktop

manufacturer's recommendation

1" min
7" max

31"

36”

x

min & max ceiling height examples

x = 30"

min

8'

4 5/8"

max

8'

10 5/8"

x = 28"

min

8'

2 5/8"

max

8'

8 5/8"

x = 26"

min

8'

5/8"

max

8'

6 5/8"

x = 24"

min

7'

10 5/8"

max

8'

4 5/8"

20"

2

5/8”

3

3/4”

upper

chimney

cover

lower

chimney

cover

canopy

cabinet base

x = distance from hood to cooktop

(varies depending on installation)

min - 24”, suggested max - 30”

also consult cooktop

manufacturer's recommendation

3

3/8”

min

14

3/8”

max

23

5/8”

2

5/8”

36”

x

min & max ceiling height examples

x = 30"

min

7'

11 5/8"

max

8'

10 5/8"

x = 28"

min

7'

9 5/8"

max

8'

8 5/8"

x = 26"

min

7'

7 5/8"

max

8'

6 5/8"

x = 24"

min

7'

5 5/8"

max

8'

4 5/8"

Rev.04/05

WARNING! Product specifications are subject to change without notification. Consult the installation instructions

before you begin installing this rangehood.

Pre-Planning Your Ductwork

Ductless Installations*

For installations where ductwork is

impossible or highly impractical, a

ductless conversion kit is available. A

charcoal filter, which attaches under the

blower assembly, absorbs smoke and

odors. A ductless diverter assembly

directs the air out to a lower chimney

with a vent grate cut into the back.

Make your ductrun as straight and short as possible. The ductrun

should not exceed 35 equivalent feet if ducted with the required

minimum of 6” round duct. Count 45º angles as 3 feet, 90º elbows

as 5 feet, and 90º flat elbows as 12 feet.

For best results, use no more than three 90° elbows. Make sure

that there is a minimum of 24” of straight duct between elbows

if more than one is used. Do not install two elbows together. If

you must elbow right away, do it as far away from the hoodʼs

exhaust opening as possible.

Ducted

* it is highly recommended that professional style cooking always be vented to the outside.

Ductless

Dimensional Diagrams

Pre-Planning Your Installation -

Important: Consult the installation instructions before you begin installing this rangehood.

Note: The Ductless Vent

Grate exhausts toward the

rear of the chimney.

Ducted

Ductless

The ducted Axia Isola Plus chimney can be adjusted for ceilings between 7ʼ 5 5/ 8” and 8ʼ 10 5/ 8” depending on the distance between the bottom of the hood and the cooktop

(distance x in above DUCTED diagram). The ductless Axia Isola Plus chimney can be adjusted for ceilings between 7ʼ 10 5/ 8” and 8ʼ 10 5/ 8” depending on the distance

between the bottom of the hood and the cooktop (distance x in above DUCTLESS diagram).