LINE SET LENGTH AND SIZE

BTUH

SUCTION LINE SIZES

LIQUID LINE SIZES

15 ft.

25 ft.

50 ft.

75 ft.

15 ft.

25 ft.

50 ft.

75 ft.

18

3/4"

3/4"

3/4"

3/4"

3/8"

3/8"

3/8"

3/8"

24

3/4"

3/4"

3/4"

3/4"

3/8"

3/8"

3/8"

3/8"

30

7/8"

7/8"

7/8"

7/8"

3/8"

3/8"

3/8"

3/8"

36

7/8"

7/8"

7/8"

7/8"

3/8"

3/8"

3/8"

3/8"

42

7/8"

7/8"

7/8"

1 1/8"

3/8"

3/8"

3/8"

3/8"

48

7/8"

7/8"

7/8"

1 1/8"

3/8"

3/8"

3/8"

3/8"

60

1 1/8"

1 1/8"

1 1/8"

1 1/8"

1/2"

1/2"

1/2"

1/2"

Recommended liquid and suction tube line size is for standard installations. The unit charge is correct for the outdoor unit, matched indoor coil and
15 feet of refrigerant tubing. For tubing length other than 15 feet, add or subtract the amount of refrigerant, using the difference in length multiplied
by the per foot value. These recommendations do not apply to Long Line Length Installations that exceed 75 feet or where there is more than 40 feet
vertical separation between indoor and outdoor units. (Lengths in excess of 75 feet or more than 40 feet vertical separation are not recommended.)
Note: See unit installation instructions for proper installation.

*TDR required to obtain SEER rating.

EXTENDED COOLING CAPACITIES

OUTDOOR

UNIT MODEL

INDOOR UNIT

RATINGS AT

STANDARD CONDITIONS

CONDENSER ENTERING AIR TEMPERATURE DEGREES (F)

BTUH

SEER*

CFM

80

85

90

95

100

105

110

115

C18ABD1VF

AC1A024A

17,500

13

650

TOTAL

19,100

18,550

18,025

17,500

16,800

16,150

15,550

14,850

SENSIBLE

13,900

13,550

13,150

12,750

12,250

11,800

11,300

10,850

AC1A036A + FV80A070-4

18,000

14

640

TOTAL

19,700

19,100

18,600

18,000

17,400

16,900

16,300

15,800

SENSIBLE

14,300

14,000

13,800

13,500

13,200

12,900

12,500

12,100

C24ABD1VF

AC1A024A

21,600

13

810

TOTAL

23,700

22,900

22,150

21,600

20,700

19,950

19,150

18,400

SENSIBLE

17,300

16,750

16,200

15,750

15,100

14,550

14,000

13,500

AC1A042A + FV80A070-4 /
AC1A042A + FV80A085-4

21,600

14

810

TOTAL

24,000

23,200

22,400

21,600

20,600

19,800

19,000

18,200

SENSIBLE

17,900

17,600

17,300

17,000

16,600

16,300

16,000

15,700

C30ABD1VF

AC1A030A

26,600

13

1,000

TOTAL

29,150

28,300

27,500

26,600

25,650

24,750

23,850

23,000

SENSIBLE

21,300

20,750

20,100

19,500

18,750

18,100

17,500

16,800

AC1A060A + FV80A085-4 /
AC1A060A + FV80A115-5

28,000

14

1,000

TOTAL

31,000

30,000

29,000

28,000

27,000

26,000

25,000

24,200

SENSIBLE

22,200

21,800

21,400

21,000

20,600

20,200

19,800

19,400

C36ACD1VF

AC1A036A

34,000

13

1,150

TOTAL

37,000

36,200

35,150

34,000

32.900

31,800

30,700

29,650

SENSIBLE

27,000

26,450

25,650

24,750

24,000

23,250

22,500

21,650

AC1A060A + FV80A085-4 /
AC1A060A + FV80A115-5

35,000

14

1,150

TOTAL

39,000

37,600

36,400

35,000

34,000

33,000

31,800

30,600

SENSIBLE

27,200

26,600

26,200

25,500

25,000

24,600

24,200

23,600

C42ACD1VF

AC1A042A

40,000

13

1,350

TOTAL

43,450

42,300

41,150

40,000

38,800

37,650

36,550

35,500

SENSIBLE

31,750

30,850

30,100

29,250

28,350

27,500

26,700

25,950

C48ACD1VF

AC1A048A

44,000

13

1,550

TOTAL

47,650

46,400

45,250

44,000

42,700

41,550

40,330

39,200

SENSIBLE

34,750

33,850

33,100

32,250

31,200

30,500

29,400

28,650

C60ACD1VF

AC1A060A

53,000

13

1,750

TOTAL

56,600

55,400

54,150

53,000

51,800

50,600

49,500

48,600

SENSIBLE

41,250

40,500

39,550

38,750

37,850

36,950

36,150

35,500