Getting Started

Using the Instrument

step name start

(µs)

amplitude

start

scaled to 0-1024

step

length

amplitude

scaled to 0-511

0

0 30%

0

29 153

1 sync

pulse

1.8

0%

29

75

0

2 back

porch

6.5

30%

104

90

153

3 50%

grey 12.1

65%

194

165

332

4 white 22.4 100%

358

165

511

5 50%

grey 32.8

65%

525

165

332

6 black 43.1 30%

690

165

153

7 50%

grey 53.4

65%

854

165

332

8 front

porch 63.7

30%

1019

5

153

These values can now be entered in the staircase set-up
screens. Press EDIT then the STAIR key. You should
see this screen:

VALS=ABS AUTO=YES
STEP=00 ACTIVE
LENGTH=0256
LEVEL=+511

Change the length for the first step (00) to 29 and the level
to +153. If you use the numeric and ENTER keys to make
the change, the step number automatically increments
after the level has been entered.