Finisar XENPAK Transponder FTLX8561E2 User Manual

Page 9

Advertising
background image

FTLX8561E2 Product Specification – October 2008

© Finisar Corporation – October 2008

Rev B

Page 9

Eye Safety

Finisar FTLX8561E2 transponders are Class 1 Laser Products. They are certified per the
following standards:

Feature Agency

Standard Certificate

Number

Laser Eye

Safety

FDA/CDRH

CDRH 21 CFR 1040 and Laser Notice 50

9210176-77

Laser Eye

Safety

TÜV EN

60825-1:

1994+A11:1996+A2:2001

IEC 60825-1: 1993+A1:1997+A2:2001

IEC 60825-2: 2000, Edition 2

R 72052602

Electrical

Safety

TÜV EN

60950

R

72052602

Electrical

Safety

UL/CSA

CLASS 3862.07
CLASS 3862.87

1439230


Copies of the referenced certificates are available at Finisar Corporation upon request.



VIII. Mechanical Specifications



Pull Sleeve front face color is beige.






VII. DOM Parameters

Values

Parameter

min. typ. max. Unit

Transponder Temperature Monitor Accuracy

1)

-5

+5

°C

Laser Bias Current Monitor Accuracy

2)

-10

+10

%

Transmit Power Monitor Accuracy

3)

-3

+3

dB

Receive Power Monitor Accuracy

3)

-3

+3

dB

1)

0 to 70°C case temperature.

2)

0 to 12.5 mA.

3)

-8.2 dBm to +0.5 dBm.

Values

Parameter Symbol

min. typ. max.

Unit

Module Retention Force (latch strength)

F

RET

200

N

Module Insertion Force

F

IN

40 N

Module Extraction Force (with kick-out)

F

EXT-K

16 N

Module Extraction Force (without kick-out)

F

EXT

25 N

Advertising